Gas automatic fire extinguishing system SAP9 ET "Raduga-9"


 

Purpose:

    The fire alarm and automatic fire SAP9 ET "Raduga-9", designed to equip the traction units PEI series. The system is designed to detect the fire, sound and light warning of fire and manual or automatic extinguishing a fire in the protected areas. Climatic versions of U2 in accordance with GOST 15150.

Specifications:

Nominal power supply voltage, V:

48

 Wiring Diagram

two-wire

 

The sensitivity of the system for fire alarm ИПК-ТУ is equal to:

- At flues absorbance air should be from 0.05 to 0.20 dB / m at an air speed allowable in the compartment is not more than 10 m / s;

- The thermal channel temperature increasing rate of at least 5 º C / min;

- The thermal channel threshold response temperature (70 ± 3) º C and (90 ± 5) º C.

The system generates a signal when exposed to the fire to the receiving window of any of the optical sensors OD22 flame radiation lubricants (POL) at a temperature not lower than 800 º C, of not less than 0.3 m × 0,3 m, at not more than 2 m .

 

 

Fire suppression is Chladones 125 located in the modules gas fire МГП-16-25, МГП -16-40.

The parameters of the electric starter module:

- DC voltage - 24V (20 to 27);

- Consumption current, A - from 0.45 to 0.55.

Mass of HFC 125 gas fire in modules:

- МГП -16-25 - 22.5 kg;

- МГП -16-40 - 36.0 kg.

 

If you have any questions, please do not hesitate to contact us by e-mail: admin@npoelm.ru

 




New


Ask a question about:

Gas automatic fire extinguishing system SAP9 ET "Raduga-9"

Asterisk (*) marked fields are required.

Order products:

Gas automatic fire extinguishing system SAP9 ET "Raduga-9"

Asterisk (*) marked fields are required.